Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/10/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - NO COMPLIANCE WITH NOTES FROM PREVIOUS INSP. - BE ADVISED THAT SMOKE DETECTORS ARE REQUIRED IN ALL BEDROOMS, MUST BE 3' AWAY MIN. FROM COOLER REGISTERS 18" FROM CORNERS FOR CEILING MTD - PLEASE STRAP OTHER #4 GROUND TO WALL BELOW PANEL |
|
| 09/04/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SERVICE PANEL DEAD FRONT COVER NOT PER MANUF. ALSO, CIRCUIT BREAKER ARE MIXED BRANDS. MUST BE PER MANUF. OF PANEL 2. UF CABLE EXPOSED WHERE COMING INTO SHED 3. SUPPORT COOLER BOXES ON ROOF PROPERLY - USE A LISTED BRACE DESIGNED FOR THE PURPOSE 4. SMOKE DETECTORS MUST BE AT LEAST 3' AWAY FROM COOLER REGISTERS. |