Permit: T07CM03453

Parcel: 10511061R

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T07CM03453

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/04/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
11/08/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK WALL AND HARD LID COVER
11/05/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. HAVE INSULATION UNDERGROUND SCREWS
2. SELF-TAP SCREW NOT ALLOWED FOR GROUND CONNECTION
3. STRAP FLEX WITHIN 12" OF BOXES
4. IDENTIFY WHITE USED AS HOT IN SWITCH LEG - WHITE CONDUCTOR TO BE FED TO SWITCH
5. INSTA-HOT TO BE DEDICATED CKT
6. ENTRY SOFFIT J-BOXES TO BE ACCESSIBLE FROM OPENING
7. 4 1/16 BOX OVERFILLED, UNGROUNDED

PARTIAL INSPECTION
ELECTRICAL CONTRACTOR TO GO THROUGH WORK TO INSURE IT COMPLIES WITH PLAN AND NEC