Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM03434
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/29/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO LATH 2) MISSING HPA HB22 PER DETAIL 10/SD1 3) RETRO FITS REQUIRED |
|
| 10/17/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PER DETAIL 18/SD4 ANCHORAGE SHOULD BE TRUSS TO SHEARWALL 2) MISSING TOP BLOCKING ON LEDGER PER DETAIL 2/SD6 WITH NAILING 6" ON CENTER OF BLOCKING 3) RAIL WALL BLOCKING MISSING PER 4/SD6 4) HOT STRAPPED PER 1/SD4 5) STOPPED INSPECTION |