Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM03434

Parcel: 105095940

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM03434

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/20/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/29/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO LATH
2) MISSING HPA HB22 PER DETAIL 10/SD1
3) RETRO FITS REQUIRED
10/17/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PER DETAIL 18/SD4 ANCHORAGE SHOULD BE TRUSS TO SHEARWALL
2) MISSING TOP BLOCKING ON LEDGER PER DETAIL 2/SD6 WITH NAILING 6" ON CENTER OF BLOCKING
3) RAIL WALL BLOCKING MISSING PER 4/SD6
4) HOT STRAPPED PER 1/SD4
5) STOPPED INSPECTION