Permit: T07CM03428

Parcel: 13506357A


Addresses:

6901 E CALLE PEGASO

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
08/24/2009 ELECTRIC - INTERMEDIATE Approved
08/05/2008 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK TO INSULATE AND SHEETROCK
2) USE GREEN GROUNDING SCREW IN METAL BOXES
3) SEPERATE NEUTRAL AND GROUNDING BARS IN SUB PANEL BEFORE FINALS
07/29/2008 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) BLOCK BATH CEILING REGISTER BOX
2) INSTALL ROMEX CONNECTORS ON METAL BOXES AND GROUND METAL BOXES
3) MAKE UP GROUND WIRES IN ALL BOXES
4) NAIL STOP ALL WIRES WITHIN 1 1/2" OF SURFACE
5) BATH GFI TO BE SEPERATE 20 AMP CIRCUIT
6) DO NOT INTERMIX #12 AND #14 WIRE ON SAME CIRCUIT
7) OK TO SHEETROCK DUCT IN HOUSE