Permit: T07CM03424

Parcel: 120075810


Addresses:

428 W MICHIGAN DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/10/2008 FRAMING Approved IVRS - Inspection :*
02/11/2008 FRAMING Partial Approval IVRS - Inspection :*
PENDING ALL TRADES AND SOUTH WALL
MISSING SMOKE DETECTORS
220 TO HEAT PUMP NOT INSTALLED
NAIL PROTECT
SECURE ROMEX 8" FROM BOXES
02/04/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
11/28/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL OSB EXTERIOR WALLS
2) DBL TOP PLATE BEARING WALL
3) H2.5 CLIP TOP PLATE TO RAFTERS
4) 2 X 6 CEILING RAFTERS WILL NOT ACCEPT R-30 INSULATION
11/15/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WINDOWS LACK HEADERS, TRIMMERS
2) INSTALL 3/8" OSB PER DETAILED CROSS SECTION
3) DBL TOP PLATE BEARING WALLS
4) H25 CLIP ALL TOP PLATES TO RAFTERS
5) STOPPED INSPECTION
6) RECALL 1025 APPROVAL PRIOR TO INTERMEDIATES
10/12/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/02/2007 FRAMING Not ready for Inspection IVRS - Inspection :*