Permit: T07CM03424

Parcel: 120075810


Addresses:

428 W MICHIGAN DR

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
11/07/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
11/05/2007 EXCAVATION/LAYOUT REBAR & ZON Cancelled CANCELLED PER HOMEOWNER #991-7987
11/05/2007 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) CANCELLED
11/02/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REBAR LAP SPLICES MUST BE A MIN. OF 24"
11/01/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LAP ALL REBAR JOINTS MINIMUM 24" 90'S AT CORNERS
10/30/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING 2-#4 BARS CONTINOUS FOOTER
10/12/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO EXISTING FOOTING
2) PROPOSED FOOTING NOT PROVIDED PER APPROVED DRAWING
3) POST AT CENTER BEAM EAST WALL MUST EXTEND, IN 1 PIECE FROM BEAM TO FTGS
4) ROMEX CONNECTORS REQUIRED-ALL METAL J BOXES STAPLE WIRES WITHIN 12" OF J BOX
5) REQUIRED R-30 CEILING INSULATION WILL NOT FIT IN 2 X 6 RAFTERS
6) ALL J BOXES IN CEILING SHALL BE ACCESSIBLE
7) GROUND ALL METAL BOXES
8) CHECK NEW ELECTRICAL-CANNOT OVERLOAD EXISTING CIRCUIT
9) REVISE DRAWING TO REFLECT AS BUILT
10) HAVE REASON DOING WORK ON SITE AT NEXT INSPECTION
10/02/2007 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) NO APPROVED PLANS ON SITE
2) RECALL WHEN READY
3) MAKE SURE ALL WORK IS PER APPROVED PLANS