Inspection History: FRAMING

Permit Number - T07CM03423

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/19/2007 FRAMING Approved IVRS - Inspection :*
11/16/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREBLOCK AT EACH SIDE BAY WINDOW
2) CHECK DROP AT ENTRY TO LIVING ROOM
3) SHIM TRUSSES AND CUT OFF TOP PLATE AT 3 PT BEARING LAUNDRY
4) BANG PLATE TRAP ARM, H20 LINES HALL BATHROOM LAV
5) NEED HANTER AT DBL 2 X 6 SUPPORTING TRUSS FRONT BEDROOM HALL ENTRY CEILING, MARKED ON FLOOR
6) OVERSPAN MASTER SHOWER DIVERTER STUD
7) 12" TO CAN, PEX LINES AT SHOWER
8) BLOCK MECH MASTER TOILET
9) MASTER BEDROOM, SHEARWALL HOLE CUT FOR RECEPT, PEX DAMAGED-HAVE PLUMBER CHECK
10) PEX AT REAR HOSE BIB MASTER BED TOP PLATE BANG PLATE EDGE NEED J-HOOK LIFT PIPE OFF PLATE