Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM03423
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/19/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/16/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIREBLOCK AT EACH SIDE BAY WINDOW 2) CHECK DROP AT ENTRY TO LIVING ROOM 3) SHIM TRUSSES AND CUT OFF TOP PLATE AT 3 PT BEARING LAUNDRY 4) BANG PLATE TRAP ARM, H20 LINES HALL BATHROOM LAV 5) NEED HANTER AT DBL 2 X 6 SUPPORTING TRUSS FRONT BEDROOM HALL ENTRY CEILING, MARKED ON FLOOR 6) OVERSPAN MASTER SHOWER DIVERTER STUD 7) 12" TO CAN, PEX LINES AT SHOWER 8) BLOCK MECH MASTER TOILET 9) MASTER BEDROOM, SHEARWALL HOLE CUT FOR RECEPT, PEX DAMAGED-HAVE PLUMBER CHECK 10) PEX AT REAR HOSE BIB MASTER BED TOP PLATE BANG PLATE EDGE NEED J-HOOK LIFT PIPE OFF PLATE |