Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T07CM03416
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/08/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
02/26/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. STEAM ROOM FIXTURE TO BE FOR WET LOCATION 2. USE APPROVED STRAPS OK WALLS AFTER CORRECTIONS |
|
02/05/2008 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. WATER BOND TO BE ACCESSIBLE OK EXTERIOR WALL EXCEPT AS NOTED ROOM 103, 106, 107 *AGAIN: DO NOT ONE SIDE UNTIL CLEARED |
|
01/10/2008 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* DO NOT ONE SIDE 1. NO MORE THAN 360 DEG. IN CONDUIT RUNS 2. INSTALL ALL PLASTER RINGS 3. JUNCTION BOX TO BE ACCESSIBLE 4. PROTECT PVC CONDUITS AT BASE PLATE |