Permit: T07CM03406

Parcel: 120052720


Addresses:

904 W IRVINGTON RD


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T07CM03406

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
04/02/2008 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
03/24/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO TOP OUT RETAINING WALL
03/20/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PRE-GROUT 1ST LIFT CENTER SECTION OK
03/19/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
WRONG REBAR
03/14/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
03/13/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR WING RETAINING WALL FOOTING
03/12/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
ROCK POCKETS OK
03/11/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
WEEP HOLES CAULKED
03/07/2008 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
NEEDS REVISED PLANS SHOWING DETAIL FOR NEW LIGHT CAISSONS
03/06/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR BASIN RETAINING WALL TO 4'
NEEDS SPECIAL INSPECTION FOR EPOXIED REBAR
02/29/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR BASIN RETAINING WALL TO 4'
02/27/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR BASIN RETAINING WALL FOOTING
02/26/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR SIDEWALK AROUND KIOSK
02/19/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR WEST END UNDER CANOPY AND TANK FILL AREA
02/15/2008 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
NEEDS 3/4" X 24" SMOOTH DOWELS AT CONST. JOINT
02/14/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR FROM A WEST PORT OF CANOPY SLAB
02/11/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
EAST TO GRID LINE A OK TO POUR
01/30/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR KIOSK FOOTING & SLAB
12/20/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR CANOPY COLUMN FOOTINGS