Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM03404
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/30/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
|
09/28/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) CLOSET FLANGE TO SIT 1/4" ABOVE FINISHED FLOOR |
|
09/20/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) POST YOUR SITE NUMBER 2) CORRECTION MADE OK 3) OK TO COVER 4) NEED TO SEE CLOSET FLANGE SECURED TO THE FLOOR |
|
09/19/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) OK TO COVER UNDERGROUND 2) NEED TO SEE CLOSET FLANGE 3) TRAP ARM MAY NOT CHANGE SIZE 4) TRAP AND TRAP ARM TO BE THE SAME SIZE 5) TRAP MAY BE ONLY ONE SIZE LARGER THAN TAIL PIPE TO WHICH IT IS CONNECTED 6) LOW TAIL PIECE IS 1'-1/4" |
|
09/18/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* |