Permit: T07CM03387

Parcel: 12706010A


Addresses:

40 N SWAN RD 01


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T07CM03387

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/28/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
02/28/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
02/27/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
INSTALL BACKING AND SECURE MOP SINK BRACKET
TERMINATE DRAINS
ADJUST LAV FAUCET RUN TIMES
UPSTAIRS TRS AND LOUNGE RMS 207 & 205 OK TO USE
02/08/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
DN STAIRS BR SINK OK
URINAL PIPING IN WALL OK
BE SURE YOU HAVE 6" FOR WATER CONN. CRITICAL LEVEL
02/04/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) DN STAIRS FIXTURES OK TO USE
2) ONLY ONE SLIP NUT ALLOWED ON STREAM OF P-TRAP. SCRAPE OFF PAINT PRIOR TO MAKING SOLVENT ? JOINT ON ABS. 6" REQUIRED FOR CRITICAL LEVEL ABOVE URINAL
3) CAULKING ON URINAL AND BREAKE ROOM SINK
4) PROVIDE MIN. CLEARANCES FOR W.C. AND URINAL IN MENS TR 212. SEE PLAN PAGE A4.1 FOR SPECIFIED DIAMENATIONS
01/15/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*