Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/12/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 02/11/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* AG AND RIGID TUBE FOR ICE BIN DRAIN |
|
| 02/08/2008 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* MISSING C O PLUG AT HS LABELS FOR 140 DEG HW NO PLUMBING ISSUES PREVENTING TCO |
|
| 02/06/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 12 PM NOT READY NO VALVES ALLOWED DNSTRM OF AAV BACKFLOW DEVICES SHALL BE INSTALLED AT 5' OR LESS ABV FLOOR OR PLATFORM PROVIDE BF CERTS. EXPOSE HAMMER ARRESTORS AT WASHER BOX AIR GAPS AT ID WASTE PIPING LIST NOT COMPLETE |