Permit: T07CM03360

Parcel: 141314300

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM03360

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/24/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/17/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL VERTICALLY STUDS AT SHEARWALLS ATTACHED TO H.D. OR P.A.'S-NAIL STUDS TO SHEAR
2) NEED TRUSS DRAWS, TO DETERMINE IF HIP JOINT GETS A HANGER AT (DBL GIRDER, BACK NAILED)
3) OSB ROOF SHEATHING DELAMINATING, PLEASE HAVE SUPPLER CHECK PRODUCT
4) BLOCK OSB TRIANGLE TURNED WRONG WAY AND PLUG SMALL HOLE