Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T07CM03356
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/12/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
12/10/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NO PLAN ON SITE 2. IS RECEP MISSING L/R WALL SOUTH OF PANTRY? 3. NO VACUUM BREAKER SOUTH HOSE BIB 4. CONNECT GAS ON FIREPLACE 5. CONNECT DISHWASHER 6. WATER HEATER VENT HAS NEGATIVE PITCH 7. ACCESS PANEL TO ALLOW FOR REPLACEMENT OF PUMP ON WHIRLPOOL TUB IS REQUIRED. 2006 IRC P2720.1 |