Inspection History: BUILDING - FINAL

Permit Number - T07CM03356

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/12/2007 BUILDING - FINAL Approved IVRS - Inspection :*
12/10/2007 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NO PLAN ON SITE
2. IS RECEP MISSING L/R WALL SOUTH OF PANTRY?
3. NO VACUUM BREAKER SOUTH HOSE BIB
4. CONNECT GAS ON FIREPLACE
5. CONNECT DISHWASHER
6. WATER HEATER VENT HAS NEGATIVE PITCH
7. ACCESS PANEL TO ALLOW FOR REPLACEMENT OF PUMP ON WHIRLPOOL TUB IS REQUIRED. 2006 IRC P2720.1