Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/15/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PRESSURE TEST NOT HOLDING 2. REPAIR LEAKSD AND CALL BACK FOR INSPECTIONS |
|
| 10/02/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 201 N STONE - WATER HEATER PERMIT 3# TEST BONDING TO COLD RECONNECT VENT REMOVE TAPE |
|
| 08/10/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. EXTERIOR PIPING TO MAINTAIN 3 1/2" ABOVE GRADE AT ALL POINTS 2. SEAL EXTERIOR WALL PENETRATIONS 3. WATER HEATER REQUIRES A VENT, A DRIP LEG, EXTEND T&P RELIEF DRAIN 4. WATER HEATER TO SIT 3" ABOVE SURROUNDING GRADE ON AN APPROVED BASE 5. BOND GAS PIPE TO WATER PIPE #6 6. USE APPROVED VALVES AGA/CSA 7. REMOVE AND CAP OFF FURNACE |