Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/28/2008 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* 1) OK FOR CONCRETE POUR |
|
| 02/26/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) (3) POST FOOTINGS FOR PORCH COLUMNS ONLY |
|
| 10/29/2007 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) EXPOSE FOOTING TO A DEPTH OF 12" 2) OUTSIDE ELECTRIC OUTLETS MUST BE GFCI PROTECTED WITH WEATHER PROOF COVERS WEST WALL 3) ELECTRIC OUTLETS HAVE OPEN GROUNDS IN AZ ROOF 4) CEILING FAN CANNOT EXTEND BELOW 7 FEET 5) CEILING FAN CANNOT BE POWERED BY ZIP CORD 6) PROVIDE 6" CLEARANCE TO WOOD FROM WOOD STOVE VENT OR REMOVE WOOD STOVE 7) REMOVE FRONT OVER HANG PER PLAN 8) STOPPED INSPECTION |