Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/09/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/15/2008 | PLUMBING - INTERMEDIATE | Denied | 3" CLOSET STUB IS CUT TOO SHORT EXTEND PIPE TO ELIMINATE FOULING LEDGE AND PROVIDE CORRECT SOLVENT WELD JOINT. ALSO, BRASS SCREWS ARE REQUIRED. SHOWER LINERS COVERED WITHOUT INSPECTION |
|
| 06/06/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER RECALL INSPECTION FOR CLOSET FLANGE AND SHOWER PAN LINER |
|
| 06/05/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* CONTINUED DENIED INSPECTIONS WILL RESULT IN REFEE |
|
| 06/03/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SEE PREVIOUS CORRECTIONS FOR WC VENT AND WATER PIPE SIZING 2. CHECK VTR LOCATION FOR CLEARANCE FROM AIR INTAKE OF FURNACE 3. CORRECT PIPE SUPPORTS ON ROOF, NO BRICKS, TAR BLOCKS TO ROOF 4. PROVIDE INSTALLATION INSTRUCTIONS FOR WH |
|
| 02/28/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - EXTERIOR SEWER NOT PER PLAN - REDLINE ON SOIL PIPING - PROVIDE MIN. REQUIRED SLOPE - VENT TAKE OFF SHALL BE ABOVE FLOW LINE (ROLL YOUR WYE UP TO A TRUE 45 DEG.) - IN WALLS, SWEEP REQUIRED ON TRAP ARM - PROPERLY SUPPORT WATER TUBING - NAIL ALL FOUR SIDES ON STUB OUT SUPPORTS - USE APPROVED CLAMPS AT DIVERTER VALVES AND AT VENT PENETRATION - REMOVE CONCRETE CHUNKS AND DIRT FROM PIPING - WATER PIPING NOT PER PLAN - GAS NOT PER PLAN - 1" WATER CONN. OUTSIDE OK TO COVER |