Permit: T07CM03312

Parcel: 134163660

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/19/2007 FRAMING Approved IVRS - Inspection :*
12/18/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RE-NAIL WEST GARAGE SHEAR OSB-NAILS TO DEEP
2) MOVE ROCK OFF N. KITCHEN WALL
3) MOVE INSULATION CARD BOARD BAFFLE OFF "B" VENT IN LAUNDRY
4) CORRECT NEGATIVE PITCH ON LAV IN SOUTH BATH
5) FINISH SURROUND INSULATION IN BATHS
6) BANG POWDER ABS ON 2ND FLOOR
7) CAULK COMB AND RELIEF VENTS, STOVE VENT AND WEST ENTRY FASCIA
8)
12/14/2007 FRAMING Not ready for Inspection IVRS - Inspection :*