Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T07CM03300
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2010 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* 1) NEED 110 AMP BREAKER AND CLIP OR SCREW TO HOLD BREAKER 2) CALL BACK FOR FINAL |
|
03/26/2010 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) NEED RICK OR RICH TO REINSPECT |
|
10/02/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK WALLS |
|
10/01/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* FINISH PREVIOUS ITEMS 2 & 5 |
|
09/26/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. PROTECT NM CABLES AT TOP PLATES 300.4 2. SUPPORT NM CABLE 12" FROM BOXES 3. TIGHTEN LOOSE FITTINGS 4. CORRECTLY IDENTIFY CONDUCTOR PER 200.7 & 210.5 (C) AMENDMENT 5. PLEASE VERIFY BOX FILL 314.16 6. WALL COVER WITHOUT INSPECTION PLEASE OPEN TO INSPECT. |