Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/19/2007 FRAMING Approved IVRS - Inspection :*
10/15/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER HORACE
10/10/2007 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) EXTERIOR CLIP NOT APPROVED. PROVIDE ENGINEER OF RECORD AND CITY OF TUCSON APPROVED REPAIR
2) TITAN ANCHOR BOLT REQUIRED WITHIN 12" OF SHEARWALL SILL PLATE IN GARAGE TWO LOCATIONS
3) SHEARWALL 10 REQUIRES ENDS AND EDGES NAILED AT 4" ON CENTER
4) SEAL SECOND FLOOR PENETRATIONS UNDER TUB
5) ANCHOR BOLTS REQUIRED WITHIN 12" OF SILL PLATE SPLICES
6) SEDGE ALL ANCHOR BOLTS NOT ALLOWED ON EXTERIOR SHEARWALLS
7) DUCT WORK NOT COMPLETE
8) ATTIC ACCESS OBSTRUCTED BY WIRES, DUCTWORK AND DISONNECT
9) GARAGE MAN DOOR REQUIRES TWO KING STUDS
10) STOPPED INSPECTION-TOO MANY ITEMS