Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/18/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HANGER USE 16D HANGER NAILS 2 1/2" LONG 2) EXPOSE TRIM STUDS FOR NEW HEADER 6 X 10 3) TRUSSES ON NORTH WALL TO BEAR ON EXTERIOR WALL NOT INTERIOR, CUT TOP PLATE LET RAFTER COME DOWN OR SHIM AT EXTERIOR WALL, DON'T LET BOTTOM CHORD TOUCH TOP PLATE AT INTERIOR 4) ADD BLKS BETWEEN EXISTING TRUSSES AT BEARING PT. |
|
| 11/13/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLAN CALLS FOR 18' X 11' ADDITION. ACTUAL MEASUREMENT OF ADDITION 20" X 11". YOU MUST BUILD TO PLAN OR HAVE PLAN REVISED TO AS BUILT 2) 6" X 10" BEAM CARRING 3 FULL LENGTH TRUSSES CANNOT BEAR ON A 2 X IN THE FLAT AT THE KITCHEN WINDOW. KITCHEN WINDOW HAS NO HEADER 3) NO ROOF INSPECTION MADE |