Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/22/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* SECURE HOT SIDE STUB OUT |
|
| 02/21/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* LETTER FOR CHANGE OF MATERIAL PER M.SADRISABET IS OK INSTALL VENT DOWNSTREAM OF TRAP ARM |
|
| 02/20/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - LETTER ALLOWING ALTERNATE MATERIALS FROM P.E.T IS NOT ACCEPTED. - MEHRAD SADRISABET IS THE ENGINEER OF RECORD ACCORDING TO APPROVED PLAN. INSTALL PER PLAN. - TEST FITTINGS SHALL BE INSTALLED IN CORRECT DIRECTION OF FLOW - POINT OF VENT SHALL BE ABOVE FLOW LINE - DW LOOP NOT TESTED - ICE MAKER AND DW REQUIRE HAMMER ARRESTORS AT FINAL |
|
| 02/07/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* NOT PER PLAN P-1 HAS 2 OPTIONS, NEITHER OPTION ALLOWS CONNECTION TO CO FITTING. CO IS TO REMAIN ALL FITTINGS SHALL BE DRAINAGE FITTINGS C1 SPECIFIED ALSO TYPE L COPPER SPECIFIED ALL PIPING SHALL BE PROPERLY SUPPORTED ALL PIPING SHALL BE TESTED |