Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM03243

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/10/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/05/2007 EXT METAL CLIPS/EXT SHEATHING Denied 1) WRONG SIZE NAILS IN P.A.'S (REAR WALL)
2) MISSING WIND BRACES WEST SIDE 2ND FLOOR REAR
3) 11/S1.1 SHOWS OSB UP TO TOP CHORD OF TRUSS SW9 SHEAR
4) NEED INSPECTION HOLE EAST 2ND FLOOR BEDROOM BOTTOM PLATE FLOOR DECK ONLY UNDER 1/2 OF BOTTOM PLATE