Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM03238
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/30/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) CHECK SHEAR TRANSFERS AT INTERMEDIATE INSPECTION |
|
| 08/29/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) AT INTERMEDIATE INSPECTION LOOK FOR A 35 DETAIL 10/DT1 |
|
| 08/27/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FINISH SHEAR TRANSFER, FRONT AND REAR WALLS 10/DT1 2) MISSED 4'-0" OF ROOF NAILING ABOVE FRONT BEDROOM MARKED IN BLACK 3) MISSING VERTICALS IN REAR GABLE TRUSS, STUCCO NAILING 4) EXTEND SHEAR BOX FOR INTERIOR SHEAR TRANSFER, THEN ANIL TO ROOF DECK ONE PANEL 5) SHIM BETWEEN DBL TOP PLATE AND REAR TRUSS, AT SHEARWALL ONLY GAP IS TO BIG |