Permit: T07CM03200

Parcel: 138231070

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
12/07/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
11/14/2007 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST ADDRESS VISIBLE FROM STREET
2) REMOVE SANITARY TEE FROM WATER CLOSET DRAIN. REPLACE WITH COMBO DIRECTIONAL FLOOR FITTING
3) TRACER WIRE ALL ABS AND YARD WATER LINES
4) PER SITE PLAN WEST SET BACK MUST BE 8'-0". PROVIDE SURVEYED PROPERTY PINS TO VERIFY PROPERTY LINE
5) COMPLY WITH DETAIL 3/A-3 REBAR SCHEDULE