Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM03196
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/20/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK REGISTER BOOT POWDER ROOM AND MASTER CLOSET 2) FIRE STOP CHASE MASTER CLOSET 3) CORRECT AA OPENING 4) SUPPORT ABS MINIMUM EVERY 4' 5) NEED 6" CLEAR PEX TO B-VENT 6) NO DWV TEST 7) CORRECT SLOPE 3" ABS GARAGE 8) NEED PIPE TO ISLAND 9) NEED 1" CLEARANCE TO B-VENT |