Permit: T07CM03196

Parcel: 126211470

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM03196

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/21/2007 FRAMING Approved IVRS - Inspection :*
11/20/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK REGISTER BOOT POWDER ROOM AND MASTER CLOSET
2) FIRE STOP CHASE MASTER CLOSET
3) CORRECT AA OPENING
4) SUPPORT ABS MINIMUM EVERY 4'
5) NEED 6" CLEAR PEX TO B-VENT
6) NO DWV TEST
7) CORRECT SLOPE 3" ABS GARAGE
8) NEED PIPE TO ISLAND
9) NEED 1" CLEARANCE TO B-VENT