Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T07CM03191

Parcel: 140252450

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
07/22/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
07/21/2008 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
1) HEAT STRIP TO LARGE AMPS FOR #10 CU
2) PANEL SCHEDULE CALLS FOR A.H. AT #12
07/17/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXTERIOR LIGHTS MISSING AND NO ADDRESS
2) INSTALL ANTI-TIP FOR RANGE
3) INSTALL DRAIN HOSE FOR DISHWASHER
07/16/2008 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1) PAGE 20 OF INSTALL BOOK
2) IRC M1411.3.1 #4 AUXILLIARY DRAIN (CONDENSATE)
3) CHANGE FUSES, MARK FURNACE LABEL FOR COMPONENT
07/14/2008 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*