Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2008 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/07/2008 | FRAMING | Denied | NOT READY | |
| 01/04/2008 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 12/28/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* GATE LOCKED 9:03 AM ON THE 17TH - I CAME BACK 3 TIMES BECAUSE THIS GATE WASN'T OPEN. IF YOU NEED TO LEAVE A MESSAGE FOR THE INSPECTOR TO CONTACT YOU, PLEASE DO SO. THANK YOU. |
|
| 12/17/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) THIS HOUSE NOT READY FOR INSPECTION: STUCCO CAULK ALL PENETRATIONS PATCH AT FRONT COLUMN 2) RISER AT SERVICE NOT PLUMB NOT SECURED, OR WRAP AND NO ADDRESS 3) MECH IS INCOMPLETE BEING INSTALLED NOW SECURE CONDENSATE LINE AT EXT. 4) NEED TUB BACKING 5) NAIL PROTECTION WIRE AND PIPES MISSING THRU OUT 6) STAPLES MISSING ROMEX WEST BATH 7) NO DWV TEST, NO POTABLE H20 PRESSURE 8) PLAN CALLS FOR #12 CU AIR HANDLER VERIFY IF THERE IS A HEAT STRIP 9) STUDS MISSING IN CLOSET WALL NEXT FURNACE 10) ROMEX OUTSIDE WALL AT MASTER TUB 11) STOPPED INSPECTION |
|
| 12/12/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE ENTRY AND MAIN SERVICE 2) SEAL PENETRATIONS 3) REINFORCE WINDOWS AND DOORS 4) BROKEN WINDOWS 5) INSTALL ADDRESS RAISED METAL LETTERS 6) WRAP RISER |