Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM03162
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/06/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
08/29/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEARWALL SOUTH OF KITCHEN EXTERIOR DOOR TO BE SHEATHED THROUGH DOOR WALL PER PLAN 2) SHEARWALL SOUTH OF FRONT DOOR EXTENDED TO 2 X 6 SHEARWALL GOING WEST PER PLAN 3) RISER NEEDS CLAMP 4) EXTEND SHEARWALL BEHIND ELECTRICAL PANEL PER PLAN 5) PROVIDE SUPPORT UNDER EJ RAFTERS AT ROOF |