Permit: T07CM03142

Parcel: 141350580

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM03142

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/25/2007 FRAMING Approved IVRS - Inspection :*
- CORRECT FHA STRAP NEEDED OVER MICROWAVE DUCT AT TOP PLATE
- NAIL PLATE NEEDED BOTTOM PLATE OVER 3" ABS IN GARAGE
10/24/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/23/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TIE GARAGE RAFTER IN PER 502 DETAIL
2) BANG PLATE NEEDED SILL PLATE GARAGE INTERIOR SHEAR
3) FILL ALL HOLES WITH PROPER NAILS IN FHA STRAP IN GARAGE
4) INSULATE BEHIND SHOWER
5) PROPER FHA STRAP OVER MICROWAVE DUCT TOP PLATE
6) MINIMUM 3/4" FIRESTOP AT TOP PLATE OF DUCT CHASE
7) FILL DWV TEST
8) PEX LINE 12" MINIMUM CLEARANCE FROM RECESSED LIGHT BATH BY FRONT DOOR