Permit: T07CM03141

Parcel: 141351990

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM03141

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/04/2008 FRAMING Approved IVRS - Inspection :*
02/01/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIX GARAGE FLOOR TRUSSES PER ENGINEER FIX AT BEAM IN GARAGE
2) FIX FIRE STOP ABOVE WATER LINE IN GARAGE
3) ANCHOR BOLT WITHIN 12" PLATE SEAM GARAGE EAST WALL
4) SEAL OPENINGS WEST SIDE GARAGE
5) LATTERAL BRACE FLOOR TRUSSES GARAGE
6) SHIM FULL BEARING OF FLOOR TRUSSES ON GARAGE WALL
7) HOLDOWN UNDER STAIRS NOT ON SHEAR PANEL
8) 5 2 X 6'S NEEDED UNDER BEAM EACH END AT FRONT OF HOUSE
9) SHIM AND NAIL HANGERS FOR FLOOR TRUSSES AT FRONT OF HOUSE
10) WIRES AGAINST GUSSET PLATES IN GARAGE FLOOR TRUSSES
11) ANCHOR BOLTS 48" ON CENTER FOR GYP SUM SHEAR IN KITCHEN
12) NAIL PLATE WATER LINES IN GARAGE
13) STOPPED INSPECTION-NOT READY