Permit: T07CM03136

Parcel: 141352430

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM03136

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
11/08/2007 FRAMING Approved IVRS - Inspection :*
11/07/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
- NAIL OFF 2X4 TO GIRDER IN GARAGE 3-16d NAILS EVERY 16" PER 302.50
- S18 DETAIL NEEDED AT FRONT OF HOUSE PER FLOOR FRAMING PLAN
- PROPER CRIPPLES NEEDED ABOVE HEADER SOUTHEAST BEDROOM
- DRAFT STOP AROUND MAIN DUCT 2ND FLOOR CEILING
- NAIL PLATE NEEDED IN GARAGE EAST WALL
11/06/2007 FRAMING Not ready for Inspection IVRS - Inspection :*