Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
11/02/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
10/30/2007 ELECTRIC - INTERMEDIATE Denied 1) SUGGEST YOU GET ELECTRICIAN TO HELP
2) DRYER WIRES SHALL BE IN RACEWAY OR ROMEX 10-3 WITH GROUND MIN
3) NEUTRAL WIRE MISSING AT MAIN FEED TO SUB PANEL
4) ISOLATE GROUNDS AND NEUTRALS IN SUB PANEL
5) GROUND ALL LIGHT AND FAN BOXES
6) PROTECT ALL WIRES WITHIN 1 1/4" FROM FACE OF FRAME MEMBER
7) SECURE ALL WIRE WITHIN 12" OF J-BOXES