Permit: T07CM03118

Parcel: 11445262J

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/23/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
01/09/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
ORLANDO W/MC PLUMBING
DANNY G.C

- OVERHEAD COPPER IS TOUCHING METAL IN TWO PLACES AND NEEDS SUPPORT AT EACH END. ROUTE TO AVOID CONTACT WITH ELECTRICAL BOX.
- SUPPORT ABS VENT NEAR CONNECTION TO EXISTING.
09/18/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
08/22/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER PIPING TEST OK
WATER HEATER TO HAVE PAN & DRAIN,
HEAT TRAPS WITH 8' INSULATION IN & 8' INSULATION OUT OF WATER HEATER ON PIPING. PROVIDE ADDITIONAL HANGERS OVERHEAD WATER PIPING. VENT CONNECTION TO EXISTING TO BE INSTALLED CORRECTLY.