Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM03061

Parcel: 105095950

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM03061

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/18/2007 FRAMING Approved IVRS - Inspection :*
10/09/2007 FRAMING Partial Approval IVRS - Inspection :*
PARTIAL UNTIL ALL INTERMEDIATES ARE APPROVED

*OK TO SHEETROCK JUST WAITING ON SPECIAL INSPECTION FOR CONCRETE SLAB
10/08/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ADD 2 X 6 TO OVER NOTCHED STUD AT MASTER BATH
2) ADD NAILER IN KITCHEN LID FOR SHEETROCK
3) NEED STAPLES AT SOUTH EAST CORNER OF GUEST BEDROOM
4) NEED TO PROTECT HOME RUN WIRES-COMI8NG FROM PANEL THRU OSB
5) NEED SPECIAL INSPECTION FOR CUT CONCRETE IN BATHROOM
6) SPECIAL INSPECTIONS NEEDED FOR CHANGE AT BATHROOMS DUE TO CUTS IN CEMENT SLAB, DOWN TO POST TENSION CABLES. WHAT TYPE OF CONCRETE AND STRENGTH TO BE POURED BACK IN ?