Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM03061
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/18/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/09/2007 | FRAMING | Partial Approval | IVRS - Inspection :* PARTIAL UNTIL ALL INTERMEDIATES ARE APPROVED *OK TO SHEETROCK JUST WAITING ON SPECIAL INSPECTION FOR CONCRETE SLAB |
|
| 10/08/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ADD 2 X 6 TO OVER NOTCHED STUD AT MASTER BATH 2) ADD NAILER IN KITCHEN LID FOR SHEETROCK 3) NEED STAPLES AT SOUTH EAST CORNER OF GUEST BEDROOM 4) NEED TO PROTECT HOME RUN WIRES-COMI8NG FROM PANEL THRU OSB 5) NEED SPECIAL INSPECTION FOR CUT CONCRETE IN BATHROOM 6) SPECIAL INSPECTIONS NEEDED FOR CHANGE AT BATHROOMS DUE TO CUTS IN CEMENT SLAB, DOWN TO POST TENSION CABLES. WHAT TYPE OF CONCRETE AND STRENGTH TO BE POURED BACK IN ? |