Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2010 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 08/12/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT WEST WALL HOUSE SIDE OF PORCH 2) PER PLAN SPECIAL INSPECTION REQUIRED FOR ALL STRUCTUAL 3) VERT REINFORCED WITHIN 8" MASONRY CONSTRUCTION OF END OF WALL |
|
| 08/05/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) FRONT AND REAR PORCH COLUMNS TOP OFF |
|
| 07/29/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 12' ONLY/GARAGE TREP? CET? |
|
| 07/14/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 4' LIFT FRONT COLUMNS AND 12' HEIGHT MAIN NORTH & EAST HOUSE AND GARAGE |
|
| 07/02/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) REAR BALCONY COLUMNS 8'-MAIN HOUSE 8" EXCEPT BEAM POCKETS REAR BALCONY |
|
| 06/26/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 4' LIFT REAR PORCH COLUMNS/8' LIFT REAR WALL ONLY |
|
| 06/22/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT MAIN HOUSE SOUTH WALL AND WEST WALL TO SOUTH SIDE OF GARAGE |
|
| 06/04/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 4' LIFT MAIN HOUSE |
|
| 04/09/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* OK TO GROUT AND CONTINUE TO NEXT LIFT ON 2ND FLR. |
|
| 04/08/2009 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CANCELED BY CONTRACTOR |
|
| 04/01/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) INSPECTED EAST WALL AT BASEMENT AT 2ND LIFT-OK TO CONTINUE TO NEXT LIFT |
|
| 02/11/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) STAIR AREA RETAINING WALL 2) OK TO GROUT PARKING "L" SHAPED WALL TOPPED OUT 3) OK TO GROUT EXT. STAIRS SOUTH WALL 4) OK STEM BOND BEAM REAR WALL FLOOR LEVEL |
|
| 02/02/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
| 01/21/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) EXISTING APPROVED FOOTERS ONLY TO FINISHED FLOOR ONLY AND REAR PATIO WALL |
|
| 01/16/2009 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PERMIT OR PLANS ON SITE 8:45 AM |