Inspection History Details
Inspection Status: Approved
Inspection History: STEM WALL/RETAINING WALL
Permit Number - T07CM03033
Inspection Description - STEM WALL/RETAINING WALL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/10/2009 | STEM WALL/RETAINING WALL | Approved | IVRS - Inspection :* | |
09/09/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
09/08/2009 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED |
|
08/17/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) COLS PLACED THIS AM OK |
|
08/14/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) OK TO CLOSE REMAINING COLUMNS LEVEL B1 GRID LINES F,G,H |
|
08/07/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
08/06/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) LEVEL B1 COLUMNS LINES G, H AND J TO LINE 9 EXCEPT G-7 (ELEVATION ISSUE) |
|
07/30/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* PLACEMENT OK |
|
07/29/2009 | STEM WALL/RETAINING WALL | Partial Approval | REMAINING COLS LEVEL B1 AREA 1-6.5 OK TO PLACE | |
07/28/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) POURED BEFORE ARRIVAL PER SUPER SPECIAL INSPECTED 2) 6 COLUMNS E2, BCD #4, D#5 & 6 |
|
07/27/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) 5 COLUMNS CLEARANCE ON ELECTRIC CONDUIT-OK NORTH OF GRID LINE DON B1 |
|
07/23/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) COLUMN LEVEL B1 2/D,E,F; 3/B,E; 4/B,C,D,E; 5/B,D,E; 6/B,C,E-OK TO CLOSE |
|
07/15/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) PROGRESS ON COLUMN PLACEMENTS-OK |
|
07/14/2009 | STEM WALL/RETAINING WALL | Partial Approval | 1) PROGRESS OK | |
07/13/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) OK TO CLOSE ALL COLS LEVEL B1 AT 1-6/N-F |
|
07/09/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) PLACEMENT THIS AM OK-KEEP CONDUITS AWAY FROM VERT BAR |
|
07/07/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) P-(1) C,D,E,F/8,9 OK TO CLOSE 2) J/2,3,4,6 LEVEL B1 OK TO CLOSE 3) K/3.1 LEVEL B1 OK TO CLOSE |
|
07/06/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) D-E-F/8 & 9 CHECK ? VERT OUT OF TIE |
|
06/03/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) SHOTCRETE COMPLETE (LESS SOME SKIM CONT) |
|
06/02/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* PROGRESS ON LINE A - SHOTCRETE OK |
|
06/01/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. SHOTCRETE WALL LINE 1 DONE; PROGRESS LINE A OK 2. LINE 4 COLS. DONE OK |
|
05/28/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. SHOTCRETE PLACEMENT LINE 1 TO GRID B OK LOWER LEVEL LINE 1 TO GRID E ON 2ND LEVEL 2. COLUMNS PLACED OK YESTERDAY; CLOSING LINE 4 TODAY OK TO PLACE |
|
05/26/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. FORMS SET LINES 3, 5, 6 AND @ 4/F 2. CORRECTIONS MADE LINE A - OK TO COVER 3. 3 PANELS (LOWER LEVEL) LINE 1 HAD SHOTCRETE PLACED TODAY OK |
|
05/22/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* EXTERIOR WALL STEEL LINE A SUBSTANTIALLY COMPLETE OK TO BEGIN SHOTCRETE WHEN SPEC. INSP. CONFIRMS MINOR CORRECTIONS. |
|
05/21/2009 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection :* | |
05/20/2009 | STEM WALL/RETAINING WALL | Partial Approval | 1) LINE 1 OK FOR SHOTCRETE WHEN SPECIAL INSP CONFIRMS FINAL PLACEMENT OF CORNER BARS AT 1/A. 2) REMAINING COLS UP TO GRIDLINE 6 OK TO CLOSE UP; COLS 3B, 5B & 4E REQUIRE SOME ADJUSTMENT AT THE BOTTOM WHICH SPECIAL INSPECTOR MAY CONFIRM. |
|
05/18/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* WATER PROOFING GENERALLY OK SOME AREAS ALONG BOTTOM TO BE PUSHED BACK |
|
05/15/2009 | STEM WALL/RETAINING WALL | Cancelled | IVRS - RI canceled | |
05/13/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) STAIR STEM |
|
05/08/2009 | STEM WALL/RETAINING WALL | Partial Approval | 1) FOOTING FOR STAIR @ C-E/5-6 AREA OK 2) COLUMN STEEL FOR REMAINING COLUMNS B-F/3-6 OK BUT I STILL NEED TO SEE FINAL LAYOUTS BEFORE CLOSING |
|
05/05/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* GRID LINE 3/B 4/B, C, D -- OK TO CLOSE |
|
04/29/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
04/28/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* CLOSE UP OF COLS. @ 2/B, C, D, E AND 3/B, F OK OK TO PLACE |
|
04/27/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* GRID LINE 2/B,C,D,E AND 3/D AND F COL. STEEL OK; OK TO CLOSE |
|
03/25/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* CONTINUATION OK SOIL NAIL WALL OK |
|
03/19/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. OK TO PLACE CONCRETE IN COL @ E/7.1 2. PROGRESS ON SOIL NAILS OK |
|
03/18/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* MASONRY STEMS @ 1/N AND 10/M AREAS |
|
03/16/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. COL. E/7.1 OK TO CLOSE AND PLACE 2. PLACEMENT @ 7.1/D, 7/D, E, F AND J/9 OK 3. SHOTCRETE AND FINISH OK TO 1/G OK |
|
03/12/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. HOOKS ON COL. @ E/7.1 MUST ENCAGE LOWER DOWELS 2. CLEARANCE @ F/7D IS NOT SUFFICIENT @ BOTTOM 3. PROGRESS ON SOIL LINE A OK 4. PROGRESS ON SHOTCRETE LINE A OK 5. OK TO PLACE CONCRETE FOR C.I.P LINE K/LINE 9 6. OK TO CLOSE COLUMNS LINE 7/D, E, F AND J/9 |
|
03/11/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. OK TO CLOSE C.I.P WALL @ K AND 9 2. OK TO CLOSE COLUMN @ J/9 3. SHOTCRETE APPLICATION PROGRESS LINE 1 AND N LOWER TIER OK |
|
03/10/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. OK TO CLOSE UP WALLS @ SE CORNER (LINE K; LINE 9) WHEN SPECIAL INSP. GIVES OK 2. FINISH CONT TO 3/N OK |
|
03/09/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. SHOTCRETE OK TOP TIER TO N/2 2. STEEL OK FOR SHOTCRETE PLACEMENT TO 1/G BOTH TIERS |
|
03/06/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. NEW SHOTCRETE - LOWER TIER TO N/2 OK; UPPER TIER TO NS OK 2. STEEL IN OUTSIDE WALL LINE 1 TO 6 OK RECALL WHEN WIRE IN |
|
03/05/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* SHOTCRETE TO N/S UPPER TIER OK |
|
03/04/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* PROGRESS WITH SHOTCRETE LINE N LOWER TIER TO LINE 3 |
|
03/03/2009 | STEM WALL/RETAINING WALL | Partial Approval | 1) LINE N TO LINE 2 OK TO PLACE SHOTCRETE TOP AND BOTTOM TIERS. 2) TODAY'S PLACEMENT LOWER TIER TO LINE 6 OK. |
|
02/27/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. 2ND TIER (TO RAMP) SHOTCRETE PLACED TO N/7 OK 2. OK TO PLACE SHOTCRETE TO N5 OK |
|
02/26/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. SHOTCRETE PLACED TO M9 @ TOP TIER OK 2. OK TO PLACE SHOTCRETE LOWER TIER TO M/5 |
|
02/25/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* ALL PROGRESS OK |
|
02/24/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. SHOTCRETE OK TO PLACE THROUGH PANEL 20 (M/7) 2. PLACEMENT OF SHOTCRETE TOP TIER THROUGH PANEL AREA 13 OK |
|
02/20/2009 | STEM WALL/RETAINING WALL | Partial Approval | 1. TOP TIER SHOTCRETE TO LINE 6 ON 10 2. EXTERIOR WALL STEEL OK TO 1/G |
|
02/19/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* PROGRESS SHOTCRETE TO 10/H.5 1ST TIER OK |
|
02/18/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* SHOTCRETE 80 10 D |
|
02/17/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. 2ND TIER LINE K/6-7.1 OK TO PLACE 2. SHOTCRETE TOP 1/2 LINE A IN PROGRESS 3. VERTICAL STEEL ALL OF LINE 10 OK TO COVER |
|
02/13/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. EXTERIOR WALL UP TO 10/H OK TO SHEETROCK 2. 2ND TIER LINE K/6-8 OK TO CLOSE 3. SHOTCRETE OK LOWER TIER TO LINE L/8.2 |
|
02/12/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1) REGAN LINE A; INSP ON SITE; 7 YARD BATCHES; NOZZLEMAN OK APPLICATION METHOD OK |
|
02/11/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
02/10/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 2ND TIER PANEL LINE K/4-6 OK TO PLACE |
|
02/09/2009 | STEM WALL/RETAINING WALL | Partial Approval | ||
02/05/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* OK TO PLACE LINE K/6-8 AND SUMP PIT @ 9/L |
|
02/04/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* CIP WALL LINE K/6-8 OK TO CLOSE |
|
02/02/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* COLS. & WALL NOTED 1/29 CLOSED & READY TO POUR |
|
01/29/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. G&H/8; 7/H STEEL OK OK TO CLOSE COL 5 2. CLIP WALL 4-6/LINE K OK TO CLOSE 3. READY TO START SHOTCRETE 6A - 1ST CORNER IN DOG LEG |
|
01/26/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* CCS @ B/6 & C/6 |
|
01/21/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* GARAGE LEVEL - F, G, H/5 CC5 COLS. |
|
01/16/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 4 EACH CCS COLS. @ G & H/9 & 6 GARAGE LEVEL |
|
01/14/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* GARAGE LEVEL 1. CES # J & H/2; J, H, G/3; K/3.5 G,H, J/4.0 2. LINE J/7,8 OK WHEN SP. INSP. CONFIRMS |
|
01/12/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* ELEVATOR PIT OK |
|
01/07/2009 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* OK TO PLACE ELEVATOR STEMS K-H/4.7-5.5 COL @ H/5 |
|
12/19/2008 | STEM WALL/RETAINING WALL | Cancelled | IVRS - RI canceled | |
12/18/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* 1. CCS CDS LEVEL B-2 @ LINE 2/F,G,H,J; LINE 3/G,H,J LINE 3.5/K; LINE 4/G,H,J; LINE 10/J OK TO CLOSE 2. ENSURE 3 RINGS @ TOP ARE LEVEL @ VARIOUS LOCATIONS |
|
12/16/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* OK TO CLOSE STEMS AND COLS. IN ELEVATOR PITS |
|
12/15/2008 | STEM WALL/RETAINING WALL | Cancelled | IVRS - RI canceled | |
11/18/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
11/13/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* E/8 SPECIAL INSPECTIONS REVIEWED THROUGH 11/12/08 |
|
10/22/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
10/10/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* ALL SPECIAL INSPECTION THROUGH TODAY REVIEWED & ACCEPTED |
|
10/03/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* SPECIAL INSP. REPORTS FOR SOIL NAIL RETENTION WALL REVIEWED AND ACCEPTED THROUGH 10/3/08 |
|
09/25/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* SOIL NAIL AND RETENTION WALL REPORTS REVIEWED AND ACCEPTED THROUGH 9/24/08 |
|
09/19/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* SOIL NAIL/RETENTION WALL SPECIAL INSP. REPORTS REVIEWED AND ACCEPTED THRU 9/19/08 |
|
09/12/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* SOIL NAILS AND SHOTCRETE REPORTS REVIEWED AND ACCEPTED THROUGH 9/11/08 E.O.R NEEDS TO PUT IN WRITING THAT 24 DEG - 28 DEG DRILLING ANGLE OK ON BOTTOM ROW RFI OK OR EMAIL NO SEAL REQUIRED |
|
09/05/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* REVIEWED SP. INSP. REPORTS FOR SOIL WALL/SHOTCRETE REPORTS THROUGH 9/4/08 COMPLETE |
|
08/29/2008 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* REVIEWED SPECIAL INSP. REPORTS OF SOIL WALL/SHOTCRETE WALLS UP TO 8/28/08 ALL PROGRESS OK |