Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T07CM03033
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/05/2009 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* LAST CAISSON @ S/F OK TO PLACE 1. GRID 3/C, E NOT READY 3/C TOO CLOSE TO LAYOUT 2. GRID LINE 3/B 4/B, C, D -- OK TO CLOSE |
|
05/04/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
05/01/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F/6 CAISSON OK TO PLACE |
|
04/30/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* D/5 OK TO PLACE |
|
04/29/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO PLACE S/C WHEN SPECIAL INSP. CONFIRMS DEPTH OF CAISSON - ONGOING PLACEMENT 4D OF AND COLS. APPROVED YESTERDAY OK |
|
04/28/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* READY TO PLACE CAISSON @ 4/D |
|
04/27/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* STEEL CAGE AND COL. OK FOR 4/D CAISSON |
|
04/24/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection : F/4 READY TO PLACE |
|
04/22/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. E/6 PLACED OK YESTERDAY 2. C/4 STELL COL. AND CAGE OK; CAISSON OK; OK TO PLACE |
|
04/21/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. POUR @ B/5 PROGRESSING OK 2. STEEL CAGE AND COL. STEEL FOR E/6 OK; CAISSON DRILLING HAS NOT YET BEGUN |
|
04/20/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. OK TO PLACE B/4 CAISSON 2. CAGE AND COL. STEEL FOR B/5 OK 3. GRADE BEAM FOR REMAINDER OF LINE 1 & LINE A OK TO PLACE |
|
04/17/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. LINE 3/D & E - STEEL CAGE AND COL. OK OK TO PLACE CAISSONS WHEN SP. INSP. CONFIRMS FINAL DEPTH 2. REMAINING GRADE BEAM LINE A OK 3. GRADE BEAM LINE 1 A-E OK JUST FINISH CLEANING OUT AND MOVE CONDUIT 4. GRADE BEAM LINE 1 E-G FOOTING STEEL OK; VERTS NOT YET IN |
|
04/16/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* CAISSON, CAGE AND COL. STEEL OK @ C/3 OK TO PLACE |
|
04/15/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* CAISSON @ D/6 OK CAGE AND COL. STEEL OK -- OK TO PLACE |
|
04/14/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) CAISSON AND COL. OK AT F-3 READY TO PLACE |
|
04/13/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 2 CAISSONS G.L. B-2 -- B-3 |
|
04/10/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* G.L. A-1 E-2 2 CAISSONS |
|
04/09/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
04/08/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* GL 1/B-E, 2/C-D CAISSONS |
|
04/07/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
04/06/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* RECALLED FOR TOMORROW |
|
04/03/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO PLACE CAISSONS @ A/2,3,4 AND C/1 AND D1 |
|
04/02/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. BEGAN DRILLING LINE A 2. CONTINUED FILL AT LOWER RAMP PROGRESS OK |
|
03/09/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F1 FOOTINGS @ 9-10/J-N |
|
12/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* DRAINAGE SHEETS OK PER RFI OK A/5.4 CLOCKWISE TO G.4/1 |
|
12/16/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* TOWER CRANE FOOTING OK |
|
12/11/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
12/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F2 FOOTINGS @ ELEVATOR PITS (BOTH) OK TO PLACE; F1 FOOTINGS K-N/1-2 OK TO PLACE BOTTOM MAT OF TOWER CRANE OK |
|
12/09/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
12/08/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CANCELED |
|
12/04/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* E/7 AND C/6 OK TO PLACE |
|
12/03/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* C/7 D/7 YESTERDAY F-7 & B6 STEEL OK PIERS OK OK TO PLACE |
|
12/02/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
12/01/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* G/7 PIER & STEEL OK & OK TO PLACE |
|
11/26/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* CAGE & COL. STEEL OK FOR H-7 PIER OK OK TO PLACE |
|
11/25/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | G/8 and I/5.4 ok to place. | |
11/24/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. J/5 CAGE, COL/STEEL AND PIER OK PLACEMENT BEING DONE NOW 2. SPECIAL INSPECTION REPORTS REVIEWED & ACCEPTED THROUGH 11/21/08 |
|
11/21/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* H/8 READY TO SET OK TO PROCEED |
|
11/20/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* B-7 & K 5.4 OK TO PLACE |
|
11/19/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* K/4.8 & H/S CAGE & COL. STEEL OK PIERS IN PROGRESS OK TO PLACE |
|
11/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* E & F @ 7.1 (STEEL OK/GAUGE OK) PIER @ E OK PLACEMENT BEGIN PIER @ F IN PROCESS -- OK TO PLACE WHEN SPECIAL INSP. CONFIRMS BOTTOM |
|
11/14/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | REVIEWED STEEL CAGES & COLS PLUS PIERS & PARTIAL PLACEMENT OF CONCRETE @ D8 & F8 OK TO FINISH PLACING |
|
11/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
11/12/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. E/9 & F/9 PLACED OK (11/11/08) 2. C-8 CAGE & COL. STEEL OK; PIER OK OK TO PLACE |
|
11/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | D-9 OK TO PLACE | |
11/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* G-5 PLACED OK TODAY |
|
11/06/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* CAISSON STEEL & COL. STEEL OK PIER #11 OK OK TO PLACE G-4 SPECIAL INSPECTIONS FOR DRILLED PIERS AND CONCRETE SAMPLES REVIEWED AND ACCEPTED THROUGH 11/5/08 |
|
11/05/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 3 PIERS CAISSON AND COL STEEL OK G9 & G6 OK TO PLACE CONCRETE |
|
11/04/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* CAGE & COL. OK FOR G/3; DRILLED PIER OK OK TO PLACE CONCRETE |
|
11/03/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CANCELED BY CONTRACTOR |
|
10/31/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CANCELED |
|
10/30/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
10/29/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* H-9 PLACED TODAY CAISSONS & COL. STEEL FOR H4 OK PIER STILL BEING DRILLED |
|
10/28/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. H3 PIER OK/CAISON OK 2. PERIMETER GRADE BEAM CONTINUED TO J/1 |
|
10/27/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. READY TO PLACE J-9/PIER, STEEL, CAGE, COL. OK 2. #6 OK TO PLACE WHEN SP. INSP. CONFIRMS PIER DEPTH CAGE AND COL. OK |
|
10/24/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. CAGE & COLUMN STEEL OK FOR 2/G&H 2. OK TO PLACE CONCRETE @ CAISSONS WHEN CONFIRMED BY SPECIAL INSP. 3. SPECIAL INSP. LOGS FOR DRILLED PANS AND CONCRETE REVIEWED & ACCEPTED THRU 10-23 |
|
10/23/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* CAISSONS OK TO PLACE @ J6 & J7 |
|
10/22/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. CF5/CC5 OK TO PLACE @ J/3 2. SPECIAL INSP. FOR DRILLED PIERS & CONCRETE SAMPLES REVIEWED & ACCEPTED THROUGH 10/22/08 |
|
10/20/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CASE & COL OK FOR F/2; CASE & COL OK FOR J/2; CASE & COL OK FOR J/6 A. OK TO PLACE 2 F, J AND 6/J WHEN SP. INSP. CONFIRMS CAISSON DEPTH B. OK GRADE BEAM FROM LINE A @ 4.5 CLOCKWISE TO 10 @ K.5 |
|
10/19/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* (1) CAISSON J-3 |
|
10/16/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* G.L E.1.0 9-K CAISSON FOOTER (2) TOTAL |
|
10/15/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* GL 1.1-M, K.1-3.1 (2) CAISSONS TOTAL |
|
10/14/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* GL K-4.0, K-6.0, K-8.0 3 CAISSONS |
|
10/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* G.L H.G.F LINE 1.0 |
|
10/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. LINE 1/J & K; LINE M/2.0; LINE K.9/10 ALL DRILLED, CAGES READY, OK TO PLACE 2. ALL SP. INSP. THROUGH TODAY REVIEWED & ACCEPTED |
|
10/09/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
10/08/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PIERS DRILLED @ M-3, 4, 5; CASES OK -- OK TO PLACE CONCRETE ON SP. INSP. OK K.9/9 READY TO PLACE ALL POURS FROM YESTERDAY SATISFACTORY |
|
10/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* CFS/CCb @ B/8 PLACED OK; PIERS DRILLED AT 10/K.9 & K OK ALSO, 8/K.9 |
|
10/03/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* CAISSON CF6 @ B/8.0 WITH EE6 COL. FOOTING STEEL OK SP. INSP. ON SITE FOR PLACEMENT |
|
10/02/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* P.LINE 20 @ C.1, H, J --- PLACED OK PIERS DRILLED FOR 10/K & 9/B.7 OK TO PLACE TODAY |
|
10/01/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
09/30/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | PIERS DRILLED @ A/7.9 & B.1/8.4 SPECIAL INSPECTORS ON SITE TO WITNESS CGE AND CONCRETE PLACEMENT. | |
09/29/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PLACEMENT OF STEEL & CONCRETE LINE 10 CAISSONS D, E ON 9/26/08 CAISSONS F, G ON 9/29/08 CONTINUED DELAYS DUE TO CAVE IN AT BOTTOM OF DRILLED PIER |
|
09/26/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
09/25/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* WORK DELAYED |
|
09/24/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
09/22/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 2 EACH CF3 CAISSONS PLACED @ LINE A/6.7 & 7 |
|
09/19/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 2 EACH 4' X 60' CAISSONS PLACED GRIDLINE A/5 & 6 - CONCRETE PLACED BY TREMIE TO DISPLACE WATER IN SHAFT - SPECIAL INSPECTOR FOR CONCRETE PLACEMENT AND REBAR - LEFT SITE BEFORE WORK WAS COMPLETED - HIS SUPERVISOR PHIL HAYWORTH WAS NOTIFIED THAT THIS IS UNACCEPTABLE. - FURTHER DIGRESSION MAY RESULT IN SPEC. INSP. COMPANY BEING REMOVED FROM PROJECT |
|
09/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* DRILLED 2 CF3 HOLES ALONG LINE A, NO CONCRETE PLACED DUE TO WATER INFILTRATION |
|
09/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
09/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* | |
09/15/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* INSPECTED 9 EACH (ONLY 8 TAGGED) CF3 CAISSON CAGES FOR PLACEMENT ALONG GRID LINE A |