Permit: T07CM03033

Parcel: 117060940


Addresses:

45 N 5TH AV


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T07CM03033

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
05/05/2009 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
LAST CAISSON @ S/F OK TO PLACE

1. GRID 3/C, E NOT READY
3/C TOO CLOSE TO LAYOUT
2. GRID LINE 3/B
4/B, C, D -- OK TO CLOSE
05/04/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
05/01/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
F/6 CAISSON OK TO PLACE
04/30/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
D/5 OK TO PLACE
04/29/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO PLACE S/C WHEN SPECIAL INSP. CONFIRMS DEPTH OF CAISSON - ONGOING PLACEMENT 4D OF AND COLS. APPROVED YESTERDAY OK
04/28/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
READY TO PLACE CAISSON @ 4/D
04/27/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
STEEL CAGE AND COL. OK FOR 4/D CAISSON
04/24/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :
F/4 READY TO PLACE
04/22/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. E/6 PLACED OK YESTERDAY
2. C/4 STELL COL. AND CAGE OK; CAISSON OK; OK TO PLACE
04/21/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. POUR @ B/5 PROGRESSING OK
2. STEEL CAGE AND COL. STEEL FOR E/6 OK; CAISSON DRILLING HAS NOT YET BEGUN
04/20/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. OK TO PLACE B/4 CAISSON
2. CAGE AND COL. STEEL FOR B/5 OK
3. GRADE BEAM FOR REMAINDER OF LINE 1 & LINE A
OK TO PLACE
04/17/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. LINE 3/D & E - STEEL CAGE AND COL. OK
OK TO PLACE CAISSONS WHEN SP. INSP.
CONFIRMS FINAL DEPTH
2. REMAINING GRADE BEAM LINE A OK
3. GRADE BEAM LINE 1 A-E OK JUST FINISH CLEANING OUT AND MOVE CONDUIT
4. GRADE BEAM LINE 1 E-G FOOTING STEEL OK; VERTS NOT YET IN
04/16/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CAISSON, CAGE AND COL. STEEL OK @ C/3 OK TO PLACE
04/15/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CAISSON @ D/6 OK CAGE AND COL. STEEL OK -- OK TO PLACE
04/14/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) CAISSON AND COL. OK AT F-3 READY TO PLACE
04/13/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
2 CAISSONS G.L. B-2 -- B-3
04/10/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
G.L. A-1 E-2
2 CAISSONS
04/09/2009 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
INCOMPLETE
04/08/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
GL 1/B-E, 2/C-D CAISSONS
04/07/2009 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
04/06/2009 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
RECALLED FOR TOMORROW
04/03/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO PLACE CAISSONS @ A/2,3,4 AND C/1 AND D1
04/02/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. BEGAN DRILLING LINE A
2. CONTINUED FILL AT LOWER RAMP PROGRESS OK
03/09/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
F1 FOOTINGS @ 9-10/J-N
12/18/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
DRAINAGE SHEETS OK PER RFI
OK A/5.4 CLOCKWISE TO G.4/1
12/16/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
TOWER CRANE FOOTING OK
12/11/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
12/10/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
F2 FOOTINGS @ ELEVATOR PITS (BOTH) OK TO PLACE;
F1 FOOTINGS K-N/1-2 OK TO PLACE
BOTTOM MAT OF TOWER CRANE OK
12/09/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
12/08/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CANCELED
12/04/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
E/7 AND C/6 OK TO PLACE
12/03/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
C/7 D/7 YESTERDAY
F-7 & B6
STEEL OK
PIERS OK
OK TO PLACE
12/02/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
12/01/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
G/7 PIER & STEEL OK & OK TO PLACE
11/26/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CAGE & COL. STEEL OK FOR H-7
PIER OK
OK TO PLACE
11/25/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval G/8 and I/5.4 ok to place.
11/24/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. J/5 CAGE, COL/STEEL AND PIER OK
PLACEMENT BEING DONE NOW
2. SPECIAL INSPECTION REPORTS REVIEWED & ACCEPTED THROUGH 11/21/08
11/21/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
H/8 READY TO SET
OK TO PROCEED
11/20/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
B-7 & K 5.4
OK TO PLACE
11/19/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
K/4.8 & H/S CAGE & COL. STEEL OK
PIERS IN PROGRESS OK TO PLACE
11/18/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
E & F @ 7.1 (STEEL OK/GAUGE OK)
PIER @ E OK PLACEMENT BEGIN
PIER @ F IN PROCESS -- OK TO PLACE WHEN SPECIAL INSP. CONFIRMS BOTTOM
11/14/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval REVIEWED STEEL CAGES & COLS PLUS PIERS & PARTIAL PLACEMENT OF CONCRETE @ D8 & F8
OK TO FINISH PLACING
11/13/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
11/12/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. E/9 & F/9 PLACED OK (11/11/08)
2. C-8 CAGE & COL. STEEL OK; PIER OK
OK TO PLACE
11/10/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval D-9 OK TO PLACE
11/07/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
G-5 PLACED OK TODAY
11/06/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CAISSON STEEL & COL. STEEL OK
PIER #11 OK
OK TO PLACE G-4

SPECIAL INSPECTIONS FOR DRILLED PIERS AND CONCRETE SAMPLES REVIEWED AND ACCEPTED THROUGH 11/5/08
11/05/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
3 PIERS CAISSON AND COL STEEL OK G9 & G6
OK TO PLACE CONCRETE
11/04/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CAGE & COL. OK FOR G/3; DRILLED PIER OK
OK TO PLACE CONCRETE
11/03/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CANCELED BY CONTRACTOR
10/31/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CANCELED
10/30/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
10/29/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
H-9 PLACED TODAY
CAISSONS & COL. STEEL FOR H4 OK
PIER STILL BEING DRILLED
10/28/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. H3 PIER OK/CAISON OK
2. PERIMETER GRADE BEAM CONTINUED TO J/1
10/27/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. READY TO PLACE J-9/PIER, STEEL, CAGE, COL. OK
2. #6 OK TO PLACE WHEN SP. INSP. CONFIRMS PIER DEPTH CAGE AND COL. OK
10/24/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. CAGE & COLUMN STEEL OK FOR 2/G&H
2. OK TO PLACE CONCRETE @ CAISSONS WHEN CONFIRMED BY SPECIAL INSP.
3. SPECIAL INSP. LOGS FOR DRILLED PANS AND CONCRETE REVIEWED & ACCEPTED THRU 10-23
10/23/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CAISSONS OK TO PLACE @ J6 & J7
10/22/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. CF5/CC5 OK TO PLACE @ J/3
2. SPECIAL INSP. FOR DRILLED PIERS & CONCRETE SAMPLES REVIEWED & ACCEPTED THROUGH 10/22/08
10/20/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CASE & COL OK FOR F/2; CASE & COL OK FOR J/2;
CASE & COL OK FOR J/6

A. OK TO PLACE 2 F, J AND 6/J WHEN SP. INSP. CONFIRMS CAISSON DEPTH
B. OK GRADE BEAM FROM LINE A @ 4.5 CLOCKWISE
TO 10 @ K.5
10/19/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
(1) CAISSON J-3
10/16/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
G.L E.1.0 9-K CAISSON FOOTER (2) TOTAL
10/15/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
GL 1.1-M, K.1-3.1 (2) CAISSONS TOTAL
10/14/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
GL K-4.0, K-6.0, K-8.0
3 CAISSONS
10/13/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
G.L H.G.F LINE 1.0
10/10/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. LINE 1/J & K; LINE M/2.0; LINE K.9/10
ALL DRILLED, CAGES READY, OK TO PLACE
2. ALL SP. INSP. THROUGH TODAY REVIEWED & ACCEPTED
10/09/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
10/08/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PIERS DRILLED @ M-3, 4, 5; CASES OK -- OK TO PLACE CONCRETE ON SP. INSP. OK

K.9/9 READY TO PLACE

ALL POURS FROM YESTERDAY SATISFACTORY
10/07/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CFS/CCb @ B/8 PLACED OK; PIERS DRILLED AT 10/K.9 & K OK ALSO, 8/K.9
10/03/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CAISSON CF6 @ B/8.0 WITH EE6 COL. FOOTING STEEL OK
SP. INSP. ON SITE FOR PLACEMENT
10/02/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
P.LINE 20 @ C.1, H, J --- PLACED OK
PIERS DRILLED FOR 10/K & 9/B.7 OK TO PLACE TODAY
10/01/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
09/30/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval PIERS DRILLED @ A/7.9 & B.1/8.4 SPECIAL INSPECTORS ON SITE TO WITNESS CGE AND CONCRETE PLACEMENT.
09/29/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PLACEMENT OF STEEL & CONCRETE LINE 10
CAISSONS D, E ON 9/26/08
CAISSONS F, G ON 9/29/08

CONTINUED DELAYS DUE TO CAVE IN AT
BOTTOM OF DRILLED PIER
09/26/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
09/25/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
WORK DELAYED
09/24/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
09/22/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
2 EACH CF3 CAISSONS PLACED @ LINE A/6.7 & 7
09/19/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
2 EACH 4' X 60' CAISSONS PLACED GRIDLINE A/5 & 6

- CONCRETE PLACED BY TREMIE TO DISPLACE
WATER IN SHAFT
- SPECIAL INSPECTOR FOR CONCRETE PLACEMENT AND REBAR - LEFT SITE BEFORE WORK WAS COMPLETED
- HIS SUPERVISOR PHIL HAYWORTH WAS NOTIFIED THAT THIS IS UNACCEPTABLE.
- FURTHER DIGRESSION MAY RESULT IN SPEC. INSP. COMPANY BEING REMOVED FROM PROJECT
09/18/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
DRILLED 2 CF3 HOLES ALONG LINE A, NO CONCRETE PLACED DUE TO WATER INFILTRATION
09/17/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
09/17/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
09/15/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
INSPECTED 9 EACH (ONLY 8 TAGGED) CF3
CAISSON CAGES FOR PLACEMENT ALONG GRID LINE A