Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM03032
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* INSTALL AVB ON HOSE BIBB OK TO COVER ALL AREAS FLANGES OK |
|
03/27/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. ABS IS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE ENDS OF BRANCHES THEN NO MORE THAN FOUR FEET BETWEEN HANGERS. ALL VERTICAL PIPING TO BE SUPPORTED 2. PIPING MAY BE SUPPORTED TO THE STRUCTURE BUT NOT BY THE STRUCTURE. USE APPROVED STRAPS AND SUPPORTS 3. STUB OUT ALL PIPING HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 4. WATER PIPING MAY NOT PASS OVER ELECTRIC SERVICE PANEL 5. INSULATION NOT PER PLAN. SEE PLUMBING NOTE #13 SEE PLUMBING NOTE #24 INSTALLATION REQUIREMENTS 6. THIS MAY NOT BE A COMPLETE LIST CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE |