Permit: T07CM03027

Parcel: 13329001A


Addresses:

545 N CAMINO SECO


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T07CM03027

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
04/14/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
04/11/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
VENT TAKE OFF FOR GT SHALL BE ABV FLOW LINE
TRY A WYE AND A 1/6TH BEND
ALSO, USE A SWEEP AT HORIZONTAL CHANGE OF DIRECTION
01/15/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
3" GW FROM 3 COMP SINK TO BUILDING EXTERIOR OK
FS, FD AND MS PIPING OK
RETEST FOR PRE-SLAB INSPECTION
01/04/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
FROM 5' WEST BUILDING EXTERIOR THRU BUILDING RESTROOMS AREA TO END OF LINE CLEANOUTS WATER TEST TO 10' IN RESTROOM ONLY, P-9, AND FLOOR SINK, AND GREASE WASTE TO BE INSPECTED AT LATER DATE
12/31/2007 PLUMBING - ROUGH, SOIL Cancelled IVRS - RI canceled