Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T07CM03027
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/24/2008 | REINFORCED MASONRY PRE-GROUT | Approved | RETAINING WALL (SOUTH - SOUTHWEST) COMPLETE | |
| 04/04/2008 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* ALL INTERIOR & EXTERIOR CMU WALLS - TOPPED OUT MECHANICAL/ELECTRIC ROOM - OK TO GROUT |
|
| 04/03/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* MEN'S RESTROOM #102 PARTITION WALLS @ 5' MECH/ELEC ROOM #104 - WALLS TOPPED OUT @ 12'-13'8" OK TO GROUT |
|
| 04/01/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST BATHROOM WALLS (6") NORTH & SOUTH @ 10'4" OK TO GROUT PROGRESS AREAS |
|
| 03/31/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EAST BATHROOM; SOUTH 6" WALL @ 10'4", NORTH 6" WALL @ 10' MECHANICAL ROOM; NORTH WALL @ 8' EAST WALL @10'4" SCREEN WALL @ 12' WEST BATHROOM WALLS TOPPED OUT OK TO GROUT PROGRESS AREAS |
|
| 03/24/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WOMENS RESTROOM INTERIOR, NW ENTRY & SE DIVIDER @ 8' JANITOR ROOM N & W WALLS @ 8'; DRINKING FOUNTAIN PARTITION (EAST) @ 4'; POP-OUT EAST OF CONCESSION @ 4' - OK TO GROUT PROGRESS AREAS |
|
| 03/14/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CENTER RESTROOM DIVIDING WALL @ 8'4" TO 12'8" CONCESSION AREA N, E, WEST WALLS @ 12'8" OK TO GROUT PROGRESS AREAS |
|
| 03/10/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH INTERIOR 6" WALL @ 9'8" (4" GROUT BED TO BE INSTALLED BEHIND INTERIOR WALL; NORTH INTERIOR 6" WALL @ 9'8" -- OK TO GROUT PROGRESS AREAS. |
|
| 03/05/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* N, E, W CONCESSION WALLS @ 0"-48"; WOMENS RESTROOM N & S 6" CMU WALLS @ 4'-8' OK TO GROUT PROGRESS AREAS |
|
| 02/20/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* CONCESSION PORTION - NORTH WALL @ 3' TO 4'6" EAST & WEST WALLS @ 4'6"; SOUTH WALL @ 10' TO 13' EXTERIOR RESTROOM WALLS N, S, E, W @ 10' INTERIOR SEPARATION WALL @ 8'8"; MECHANICAL ROOM N & E WALLS @ 18" OK TO GROUT PROGRESS AREAS |
|
| 02/12/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ALL EXTERIOR WALLS (CONTINUOUS) @ 8' EAST & WEST INTERIOR PONY WALLS @ 4' OK TO GROUT PROGRESS AREAS (SPECIAL INSP. TO FOLLOW) |
|
| 02/07/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR & INTERIOR (NORTHWALL); EXTERIOR CONTINUOUS WALLS E,W,SOUTH - ALL @ 4' - OK TO GROUT PROGRESS AREAS |
|
| 12/06/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* STEM WALLS EXTERIOR CMU; INTERIOR/EXTERIOR TWO WYTHE CMU STEM WALLS - *OK TO GROUT *RFI DATED 11/21/07 FOR THE PLACEMENT OF BOND BEAMS @ FLOOR & ROOF LINES - 2 @ #5'S IN 8" WALL & 2 @ #4'S IN 6" WALLS |