Permit: T07CM03026

Parcel: 136290020


Addresses:

3951 S PANTANO RD


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T07CM03026

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
04/14/2008 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
TOP OUT AT ALL MASONRY AT RESTROOMS/CONCESSIONS
04/11/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
INTERIOR SCREEN WALLS @ RESTROOM 1ST LIFT TO 5FT OK AND WOMENS PLUMBING CHASE TOPPED OUT
04/09/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. NORTH WALL OF MENS ROOM PLUMBING CHASE TO 8'8"
2. SOUTH WALL MENS ROOM WEST HALF TO 9'8" EAST HALF TOP OUT
3. WOMENS ROOM TOP OUT @ BOTH CHASES - OK TO GROUT
04/07/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. CMU @ BOTH PLUMBING CHASE WALLS @ WOMENS RESTROOM TO 8'8"
2. SOUTH WALL MENS ROOM CHASE TO 8'8" & NORTH WALL
TO 6' - JANITORS ROOM TOP OUT, EXTERIOR CHASE TOPOUT AND DRINKING FOUNTAIN WALL TOP OUT
04/03/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL FOUR INTERIOR PLUMBING WALLS FROM 0' TO 4'
03/31/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MEN'S ROOM PLUMBING WALL FROM 0' TO 4'
INTERIOR, RESTROOM WALLS, TOP OUT AND JANITORS ROOM FROM 4' TO 8' - OUTSIDE CHASE TO 4' AFFE
03/27/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CONCESSIONS ROOM TOPOUT & 2 INTERIOR CMU RESTROOM WALL 3RD LIFT FROM 8' TO 12'
03/24/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
INTERIOR CMU WALLS FROM 4' TO 8'
2ND LIFT AND CONCESSION AREA TO 10' -- OK TO GROUT
03/19/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. MAIN BLDG. TOP OUT @ 13'
2. CONCESSIONS AREA TO 7'4" W/CLEANOUTS
03/13/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP OUT @ MAIN BLDG. PERIMETER WALLS ONLY
03/06/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MAIN BUILDING EXTERIOR CMU WALLS FROM 4' TO 8'
02/29/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCMENT STEEL @ MAIN BUILDING EXCEPT JANITOR RM (4 SIDES) AND OPENING AT MECH. ROOM
FROM 0' TO 4' AFF
11/27/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) STEM WALL COMPLETE-OK TO GROUT