Permit: T07CM03008

Parcel: 129130730


Addresses:

807 E 31ST ST

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
07/28/2008 ROOF NAILING Approved IVRS - Inspection :*
07/11/2008 ROOF NAILING Partial Approval IVRS - Inspection :*
OK TO DRY IN ROOF

1. TRUSSES AT REAR 18,17 ARE 3PT INSTALL DBL 2X8 HEADER
2. TRUSS AZG MUST SIT ON TOP OF EXISTING WALL FOR SUPPORT TOP CHORD IS NOTCHED FOR OUT RIGGERS
3. INSTALL ALL ANCHOR BOLT NUT & WASHERS
4. NEED RED HEAD A.BOLTS AT BOTTOM PLATE SPLICES
5. BLK ALL OSB TURNED WRONG WAY FROM STRENGTH ORIENTATION AND ALL PIECES UNDER 12" WIDE
6. ONE GABLE TRUSS REQUIRES A BEARING PT IN
LIVING ROOM