Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM02993
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/03/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CIRCLED ITEMS FROM LAST INSPECTION NOT DONE-ITEMS 2, 3, 5 & 6 |
|
| 09/29/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING ROOF NAILING, BLOCK OSB TURNED WRONG WAY (MARKED IN BLACK) 2) FHA STRAPS AT 2 X 6 PLATE CUT, GARAGE TO LIVING ROOM SHEAR, CHECK NAILS IN 3" ABS 3) BRING DOWN TO CONCRETE FLOOR ALL GIRDERS LOADS 4) NEED TO NAIL BLOCKS, ? ADD BLOCKS FOR SHEAR TRANSFER GARAGE TO HOUSE 5) DBL BLKS TO GO UNDER WALL ABOVE AND NAIL WITH 17/SD2 6) HUS GIRDER HANGER USE 16D SINKERS AT TOE NAILS SIDE OF HANGER |