Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM02982
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/11/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
01/09/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* MANUFACTURE TESTING SHALL BE THIRD PARTY VERIFIED PROVIDE THE LISTING FROM THE TESTING AGENCY |
|
01/08/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* - STEAM HUMIDIFIERS MAY POSE A HIGH RISK HAZARD OF CROSS CONTAMINATION AND REQUIRE A HIGH HAZARD BACKFLOW ASSEMBLY. SEE UPC TABLE 6-2 OR PROVIDE 3RD PARTY LISTING ADDRESSING POTABLE WATER CONNECTION FOR EQUIPMENT |
|
10/22/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* COMPLETE LIST FROM 10/3/07 |
|
10/03/2007 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* HANGER ON 1/2 ABV. CEILING OK WATER CONNECTION TO EQUIPMENT THAT MAY CONTAMINATE THE POTABLE SYSTEM SHALL BE PROTECTED W/AN APPROVED TYPE BACKFLOW PREVENTION ASSEMBLY. EQUIPMENT DOES NOT HAVE A USABLE AIR GAP. |