Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T07CM02971
Inspection Description - ROOF NAILING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/30/2007 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 08/20/2007 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING BOLTS POST TO BEAM CONNECTOR (LARGE GRAY) AT GARAGE 2) BEND TABS OVER AT 2ND FLOOR TRUSS GIRDER (THA) TYPE HANGERS 3) MISSED 4'-0" OF NAILING ROOF ? WEST SIDE, MARKED BLACK 4) NAIL ALL 2 X 4 THAT ATTACH TO H.D., NAIL SHEATHING 2 X 4 5) H.D. ON WEST SIDE NOT TIED TO SHEAR DIAPHRAM 6) NON-STRUCTURAL GABLE END TRUSS GARAGE CONTINOUS BEARING (SHIM UNDER BOTTOM CHORD) 7) NEED SUPPORT FOR 2ND FLOOR FRONT POP OUTS, BEARING ON GARAGE OSB 8) AT LIVING ROOM, BLKS TIED TOGETHER WITH A.35'S ARE NOT FULLY NAILED |