Permit: T07CM02968

Parcel: 141340170

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM02968

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
01/09/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/20/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) RETRO NEEDED FOR PA STRAP BY MASTER SHOWER
2) EPOXY HOLD DOWN SPECIAL INSPECTION
12/13/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
- NAIL LEDGER AT BAY
- NAIL OF NE SHEAR AT EDGE
- RETRO NEEDED FOR PA STRAP MASTER SHOWER
- EPOXY HOLDDOWNS SPECIAL INSPECTION
- CERTIFICATION & TESTING FOR 2-PLY FLOOR TRUSS
12/07/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FINISH HOLDOWNS
2) NAIL OFF RSP4'S ON EAST SIDE
3) NAIL OFF SHEAR NORTH EAST CORNER
4) CS WEST WALL AT DIFFERENT HEIGHTS
5) RETRO NEEDED FOR PA STRAP WEST WALLMASTER SHOWER
6) COIL STRAP ALL CORNERS
7) CS14 ON 6 X 6 TO UPPER SHEARWALL IN LAUNDRY
8) CS14 BETWEEN QWINDOWS WEST SIDE ABOVE GARAGE
9) COIL STRAP NORTH WEST END OF WALL BETWEEN 2ND AND 3RD BEDROOM
12/06/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED PLANS AND PERMIT ON SITE