Permit: T07CM02942

Parcel: 11205054A

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
11/30/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
11/15/2007 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
10/24/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK WALL COVER
10/19/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. WIRING NOT PER PLAN, REVISE PLAN TO REFLECT ACTUAL SCOPE OF WORK
2. NEED BUSHING FOR LOW VOLTAGE WIRING PASSING THROUGH METAL STUDS
3. USE BRACKET TYPE BOXES FOR MOUNTING TO STUDS, NOT SCREENS INSIDE OF NON-BRACKET TYPE BOXES
4. NEED NAIL PLATES WHERE HOLE FOR WIRING IS LESS
THAN 1 1/4" FROM STUD FACE