Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/11/2008 FRAMING Approved IVRS - Inspection :*
02/08/2008 FRAMING Partial Approval IVRS - Inspection :*
1) ADD STUD AT TUB/SHOWER DIVERTER END
2) BANG PLATE PER H20 LINE TOP PLATE SHOWER
3) CHECK WITH MECH 2ND CONDENSATE FOR OVER FLOW AT COIL ABOVE FURNACE
4) INSTALL ELECTRIC BOXES FOR DRYER/WASHER AT GARAGE
12/14/2007 FRAMING Partial Approval IVRS - Inspection :*
1) END WALLS DETAILS DON'T SHOW A PONY WALL ON TOP OF 8'-0" WALL, IT IS SHOWN AS A RAKE WALL UP TO BOTTOM CHORD CHECK WITH YOUR ARCHITET IT HE APPROVES SHORT WALL AT RAKE. IT NEEDS TO BE NAILED SAME NAIL PATTERN WITH 8D'S
2) NAIL ALL WALL STUDS TO OSB AT HTT HOLDOWNS