| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/22/2008 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/20/2008 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) FINISH ELECTRIC GROUND METAL BOXES 2) BACKING FOR SHOWER SURROUNDS 3) GFCI RECEPT REAR PORCH NOT WIRED 4) SHEARWALL AT KIT TO GARAGE, TIE TOP PLATE TO TRUSS WITH A34 AT 24" ON CENTER, BLOCK JOINTS PER TYPICAL DETAIL G02/S4 BOTTOM PLATE AB'S 32" ON CENTER 1/2 DIAMETER, NAILL OFF OSB 6"-12" |
|
| 01/11/2008 | FRAMING | Partial Approval | IVRS - Inspection :* 1) SOFFITS AND PORCH LIDS OK |